CS301 Pyranometer
Accurate and Dependable
Ideal for long-term deployment in harsh conditions
weather applications water applications energy applications gas flux and turbulence applications infrastructure applications soil applications

Overview

The CS301, manufactured by Apogee Instruments, measures total sun and sky solar radiation for solar, agricultural, meteorological, and hydrological applications. Its spectral range of 360 to 1120 nanometers encompasses most of the short-wave radiation that reaches the Earth's surface. Because the CS301 connects directly to Campbell Scientific data loggers, the output of this pyranometer can be collected on site, as well as remotely.

This pyranometer features an IP67-rated, marine-grade 316L connector that allows the user to easily swap sensors for recalibration or to replace damaged cables. 

Read More

Benefits and Features

  • Compatible with most Campbell Scientific data loggers
  • Designed for continuous, long-term, unattended operation in adverse conditions
  • Measurement waveband of 360 to 1120 nm
  • Dome-shaped head prevents water from accumulating on the sensor head

Images

Detailed Description

The CS301 uses a silicon photovoltaic detector mounted in a cosine-corrected head to provide solar radiation measurements. Its dome-shaped head prevents water from accumulating on the sensor head. To eliminate internal condensation, the sensor head is potted solid and the cable is shielded with a rugged Santoprene casing. The CS301 is calibrated against a Kipp & Zonen CM21 thermopile pyranometer to accurately measure sun plus sky radiation.

Specifications

Sensor Silicon photovoltaic detector mounted in a cosine-corrected head
Measurement Description Measures sun plus sky radiation
ISO Classification Class C (second class)
Light Spectrum Waveband 360 to 1120 nm (wavelengths where response is 10% of maximum)
Measurement Range 0 to 2000 W/m2 (full sunlight ≈1000 W/m2)
Output Range 0 to 400 mV (full scale output)
Absolute Accuracy ±5% for daily total radiation
Spectral Range 360 to 1120 nm
Calibration Factor 5 W/m2/mV
Cosine Correction Error ±5% at 75° zenith angle; ±2% at 45° zenith angle
Temperature Response 0.04 ± 0.04% per °C
Response Time < 1 ms
Long-Term Stability < 2% per year
Operating Temperature Range -40° to +70°C
Relative Humidity Range 0 to 100%
Sensitivity 0.2 mV/W/m2
Diameter 2.4 cm (0.9 in.)
Height 2.5 cm (1.0 in.)
Weight 65 g (2.3 oz) with 2-m (6.6-ft) lead wire

Compatibility

Note: The following shows notable compatibility information. It is not a comprehensive list of all compatible or incompatible products.

Dataloggers

Product Compatible Note
CR1000 (retired)
CR1000X
CR300
CR3000 (retired)
CR310
CR350
CR6
CR800 (retired)
CR850 (retired)

Additional Compatibility Information

Sensor Mounts

Accurate measurements require the sensor to be leveled using a 18356 leveling fixture. This leveling fixture incorporates a bubble level and three adjusting screws. The 18356 mounts to a crossarm or a tripod or tower mast using the CM225 mounting stand. The CS301 should be mounted away from all obstructions and reflective surfaces that might adversely effect the measurement.

Data Logger Considerations

One differential analog input channel per probe is required.